FAQ

How to test whether the inverter module is damaged?

How to test whether the inverter module is damaged?
key word: ac inverter  
Turn the digital multimeter to the diode gear, connect the red pen to p-, and measure R, s, t, u, V, w with the black pen. The black pen is connected with p+, and the red pen measures R, s, t, u, V, W. Whether the measured three-phase input and output values are consistent and between 400-500, that is, normal, not abnormal.